2026-10-15

Without Eddy-Current Probes, How Can Accelerometers Capture the Full Progression of Plain Bearing Damage?

Table of Content [Hide]

    When a bearing relies on sliding contact rather than rolling elements to carry the load, eddy-current probes are often a preferred monitoring option. However, installation requirements and mounting methods can result in high installation costs.


    Can accelerometers alone, without eddy-current probes, detect abnormal wear in a plain bearing and track its subsequent deterioration?

    This case provides a real-world example.

     

    Case Background

    The monitored equipment was a gas booster fan at a steel plant. The fan was an overhung centrifugal fan operating at a rotational frequency of 49.688 Hz.


    Six RONDS RH605 acceleration sensors were installed, with no eddy-current probes used. During operation, vibration data were continuously collected through the online monitoring system, while the RONDS Remote Diagnostic Center provided 24/7 remote condition monitoring and analysis.


    without-eddy-current-probes1.jpg 

     

    without-eddy-current-probes2.jpg 

     

    without-eddy-current-probes3.jpg

     

    Fault Evolution Analysis

    Based on continuously collected data, the fault development process was divided into three stages by analyzing vibration trends, time waveforms, and acceleration spectra.


    without-eddy-current-probes4.jpg

     

    Stage 1: Normal Operation

    Period: April 28, 2022, 08:00 – May 20, 2022, 08:00

    • Vibration trends: Low-frequency acceleration and velocity RMS values remained stable.

    • Time waveform: Periodic disturbances occurred at intervals corresponding to the rotational frequency, with no pronounced sharp impacts.

    • Acceleration spectrum: Prominent rotational-frequency components and multiple harmonics were observed.

     

    Analysis: Plain bearings can exhibit rotational-frequency harmonics and periodic disturbances during normal operation. These features alone do not indicate a severe bearing fault. The overall vibration trends and subsequent changes in the signals must also be considered.

     

    without-eddy-current-probes5.jpg 

     

    Stage 2: Abnormal Wear on the Bearing Surface

    Period: May 20, 2022, 16:51 – September 15, 2022, 12:00

    • Vibration trends: Overall vibration levels rose rapidly and significantly, then dropped markedly and fluctuated.

    • Time waveform: Periodic impacts at rotational-frequency intervals became sharper, with significantly increased amplitudes.

    • Acceleration spectrum: The energy of the rotational-frequency component and its harmonics increased significantly.


    Analysis: Following equipment startup, the vibration signals changed significantly, suggesting that abnormal wear may have developed on the bearing surface. Although the vibration level subsequently dropped, abnormal signal characteristics persisted. This did not necessarily mean that the bearing had returned to normal condition.

     

    without-eddy-current-probes6.jpg 

     

    Stage 3: Severe Bearing Damage

    Period: September 15, 2022, 13:31–14:11

    • Vibration trends: Overall vibration levels rose rapidly and significantly again.

    • Time waveform: Periodic impacts at rotational-frequency intervals became even sharper, with substantially increased amplitudes.

    • Acceleration spectrum: The energy of the rotational-frequency component and its harmonics increased further, and a subharmonic at 0.5X rotational frequency appeared.


    Analysis: Compared with the previous stage, the vibration signals deteriorated further, with a new subharmonic at 0.5X rotational frequency appearing in the spectrum. The combined changes in vibration trends, time-waveform impacts, and spectral components indicated significant deterioration in bearing condition, warranting prompt on-site inspection and an assessment of the need for shutdown and maintenance.

     

    without-eddy-current-probes7.jpg 

     

    Maintenance Verification

    Inspection confirmed that the fan's impeller-side plain bearing shell had fractured and suffered extensive spalling damage, consistent with the diagnostic findings.


    without-eddy-current-probes8.jpg 

     

    Key Takeaways

    (1) Accelerometers Can Be Used to Monitor Plain Bearings

    This case demonstrates that, even without eddy-current probes, accelerometers can effectively capture key vibration features throughout the deterioration process, from abnormal wear to severe damage. This provides a viable alternative for online plain-bearing condition monitoring in suitable applications.

     

    (2) Harmonics and Impact Signals Do Not Necessarily Indicate Severe Faults

    Plain bearings can exhibit rich rotational-frequency harmonics and periodic disturbances during normal operation. Vibration trends, time waveforms, and spectral changes should be assessed together to avoid misdiagnosis based on a single feature.

     

    (3) A Drop in Vibration Level Does Not Mean the Bearing Has Recovered

    After abnormal wear developed on the bearing surface, the overall vibration level dropped noticeably, but abnormal signal characteristics persisted. Subsequent data must be reviewed to assess the equipment condition; a decrease in vibration level alone does not confirm that the fault has been resolved.

     

    (4) From Harmonics to Subharmonics: Progression of Bearing Damage

    As the fault progressed, overall vibration levels rose rapidly, impact features became more pronounced, and a subharmonic at 0.5X rotational frequency appeared in the spectrum, indicating further deterioration of the equipment. An on-site inspection should be arranged promptly, and the need for shutdown and maintenance should be assessed.